FireProtect 2 AC is a mains powered detector designed for residential fire safety. Two thermistors react quickly to burning synthetic materials, and the carbon monoxide sensor sounds the alarm before the concentration level becomes dangerous. Everything complies with the latest fire safety standards. A Thoughtful design, improved mounting panel with WAGO 221 connections and in-app settings make the installation process simple and easy, providing an RPO with the ultimate user experience.
More features
Patented smoke chamber technologyDriven by global standards and best practices, Ajax has reached a whole new level of technology for residential fire safety with FireProtect 2 AC. Thanks to a unique dust-tight and insect-proof smoke chamber, a dual-spectrum optical sensor and a proprietary HazeFlow 2 software algorithm, you are guaranteed fast and accurate fire detection – ultimate safety without the stress of false alarms.
Impermeable to dust and insectsThe smoke chamber is designed to prevent any contamination that could affect detection. A unique circulation mechanism provides the optical sensor with an unobstructed field to quickly identify combustion products in the air.
Ignores cooking fumes and water steamThe smoke chamber is wired with a dual-spectrum optical sensor, which has blue and infrared LEDs with different wavelengths. It uses the most reliable real-time detection method, which directly measures the concentration of microparticles in the air. Thanks to this technology, FireProtect 2 AC can determine the size of volatile particles in the chamber and react only to smoke. Vapour and steam are ignored.
Only real threats are registeredIn-depth research into material combustion has led to HazeFlow 2, a smoke detection algorithm developed by Ajax. The algorithm simultaneously analyzes and compares the data from the dual-spectrum optical sensor via a specified pattern to distinguish smoke from vapor or steam. The detector immediately raises the alarm if the dynamic patterns indicate a real fire.
FireProtect 2 is equipped with two class A1R thermistors to detect smokeless fire threats. They offer a significant advantage in detecting a rapid temperature increase when synthetic materials burn or a fire starts by smouldering. Thermistors are located outside the enclosure to eliminate life-saving detection delays. FireProtect 2 AC is therefore ready to detect a fire as quickly as possible, even if it starts unnoticed.
Heat alarm- A temperature increase of 10°C within a minute
- Higher than +64 °C
The detector is powered by 110-240 V~ from the mains and has a built-in backup battery. Even if the power fails, the detector continues to work without problems. It is designed to detect fire quickly and reliably with a lifespan of 10 years.
Always and everywhere up to dateFor residential fire alarm systems, informing people about a fire hazard is of paramount importance. FireProtect 2 is equipped with a powerful 85 dB siren so that an alarm cannot be missed. The detector uses tones with different patterns that are impossible to ignore to indicate each alarm or event, so that the type of threat is easily recognized and the appropriate response can be made.
The SmartBracket mounting panel allows the detector position to be adjusted after installation.
Specifications
| Compatibility |
Control panels Hub Plus Hub 2 (2G) Hub 2 (4G) Hub 2 Plus Hub Hybrid (2G) Hub Hybrid (4G) Signal boosters ReX ReX 2 |
| Jeweller communication technology |
|
| Frequency bands |
866.0 – 866.5 MHz 868.0 – 868.6 MHz 868.7 – 869.2 MHz 905.0 – 926.5 MHz 915.85 – 926.5 MHz 921.0 – 922.0 MHz |
| Maximum effective radiated power (ERP) | up to 20 mW |
| Modulation of the radio signal | GFSK |
| Range of the radio signal | up to 1,700 m |
| Encrypted communication | All stored and transmitted data is protected by a block cipher with a dynamic key. |
| Frequency hopping | Radio communications use frequency hopping to avoid interception and interference. |
| Sensitive elements |
smoke sensor heat sensor |
| Smoke detection |
Dual spectrum optical sensor False alarm protection Patented smoking chamber |
| Detection of dangerous temperatures |
According to the requirements for class A1R heat detectors Requirements of EN 54-5 and BS 5446-2 standards. High temperature alarm at temperatures above 64°C Alarm for temperature peaks when the temperature rises by more than 10°C in less than 1 minute. |
| Built-in siren | 85 dB at a distance of 3 meters |
| Power supply | 110–240 V~, 50/60 Hz, 1 non-replaceable lithium battery |
| Communication loss detection | Within 15 minutes |
| Dimensions | 122 × 122 × 54 mm |
| Weight | 315 g |
| Operating temperature range | from 0 °C to +50 °C |
| Operating humidity | up to 80% |
| Full set | FireProtect 2 AC (Heat/Smoke) SmartBracket Mounting Panel Connection terminal for WAGO 221 3-conductor 2 pieces. (pre-installed in SmartBracket) Installation kit Quick Start Guide |